- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Baker, Maryam (2)
-
McLeod, Euan (2)
-
Liu, Weilin (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
& Arya, G. (0)
-
& Attari, S. Z. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Fluorescence and, more generally, photoluminescence enable high contrast imaging of targeted regions of interest through the use of photoluminescent probes with high specificity for different targets. Fluorescence can be used for rare cell imaging; however, this often requires a high space-bandwidth product: simultaneous high resolution and large field of view. With bulky traditional microscopes, high space-bandwidth product images require time-consuming mechanical scanning and stitching. Lensfree imaging can compactly and cost-effectively achieve a high space-bandwidth product in a single image through computational reconstruction of images from diffraction patterns recorded over the full field of view of standard image sensors. Many methods of lensfree photoluminescent imaging exist, where the excitation light is filtered before the image sensor, often by placing spectral filters between the sample and sensor. However, the sample-to-sensor distance is one of the limiting factors on resolution in lensfree systems and so more competitive performance can be obtained if this distance is reduced. Here, we show a time-gated lensfree photoluminescent imaging system that can achieve a resolution of 8.77 µm. We use europium chelate fluorophores because of their long lifetime (642 µs) and trigger camera exposure ∼50 µs after excitation. Because the excitation light is filtered temporally, there is no need for physical filters, enabling reduced sample-to-sensor distances and higher resolutions.more » « less
-
Baker, Maryam; Liu, Weilin; McLeod, Euan (, Optics Express)Lens-free microscopes can utilize holographic reconstruction techniques to recover the image of an object from the digitally recorded superposition of an unperturbed plane wave and a wave scattered by the object. Image reconstruction most commonly relies on the scalar angular spectrum method (ASM). While fast, the scalar ASM can be inaccurate for nanoscale objects, either because of the scalar approximation, or more generally, because it only models field propagation and not light-matter interaction, including inter-particle coupling. Here we evaluate the accuracy of the scalar ASM when combined with three different light-matter interaction models for computing the far-field light scattered by random arrays of gold and polystyrene nanoparticles. Among the three models—a dipole-matched transmission model, an optical path length model, and a binary amplitude model—we find that which model is most accurate depends on the nanoparticle material and packing density. For polystyrene particles at any packing density, there is always at least one model with error below 20%, while for gold nanoparticles with 40% or 50% surface coverage, there are no models that can provide errors better than 30%. The ASM error is determined in comparison to a discrete dipole approximation model, which is more computationally efficient than other full-wave modeling techniques. The knowledge of when and how the ASM fails can serve as a first step toward improved resolution in lens-free reconstruction and can also be applied to other random nanoparticle array applications such as lens-based super-resolution imaging, sub-diffraction beam focusing, and biomolecular sensing.more » « less
An official website of the United States government
